Ph = ρ g Q HPh: W; ρ: kg/m³; g: m/s²; Q: m³/s ; H: m of net fall.
Use when: Permanent regime; use the fall after hydraulic losses.
Intu LabUnderstanding through experienceLink head height, flow rate and useful hydraulic power.
A Pelton turbine is an action turbine. One or more rapid jets strike the wheel buckets; pressure energy is converted into speed in the injector.
The efficiency compares the power obtained to the hydraulic power available. The best operating point depends on the type of impeller, speed and settings: maximum flow does not automatically ensure the best performance.
Ph = ρ g Q HPh: W; ρ: kg/m³; g: m/s²; Q: m³/s ; H: m of net fall.
Use when: Permanent regime; use the fall after hydraulic losses.
Putile = η ρ g Q Hη: dimensionless overall efficiency.
Use when: Define whether the useful power is mechanical or electrical, and use the corresponding efficiency.
Rather high falls and lower flow rates: mountain hydroelectric development.
Sizing and controlling production groups.
Vary the jet and compare the effect of the flow rate with that of the drop height.
This sheet explains the principles and their assumptions. Educational simulation can simplify the process; an industrial model requires suitable data and validation.
Only one correct answer per question. Answer all three questions, then view the answer key.